Der Test besteht aus 80 zufälligen Fragen.
Gesamtzahl der Fragen zu diesem Thema: 147
Why is it important to check the timing of diesel engine cylinder oil lubricators?
To ensure the piston is not covering the lubrication points and blocking the flow of cylinder lubricating oil into the cylinder.
To ensure the correct amount of cylinder lubricating oil is fed into the cylinders.
To ensure cylinder lubricating oil enters the cylinders when the piston is in the required position.
To avoid excess pressure in the cylinder lubrication system.
You are witnessing someone about to faint. What are the symptoms?
The person may be very pale, and pulse is slow at first and weak.
The pulse is very fast and the person is getting cold.
The person starts to talk a lot and seems superactive.
What is the correct name of the tool shown in the illustration?
What is generally considered as the minimum safe time period before opening a crankcase door after the oil mist detector alarm has activated and the engine has been stopped?
After at least 20 minutes.
After at least 5 minutes.
After at least 10 minutes.
What is the disadvantage of using chemicals on an oil-spill on the water?
It is difficult to apply the chemicals if the oil drifts away from the ship’s side.
The chemicals make it difficult to remove the oil from the water.
It is difficult to apply chemicals if there is any wind.
The water gets a white colour, which makes it easy to detect the oil-spill.
A large electric motor is being removed from a main seawater pump with the aid of the engine room crane. Which is the best method of starting the lift from the options given?
Use the full hoist facility on the crane to “break” the motor free after slackening all of the retaining bolts.
Use the “inch up” facility on the crane to “break” the motor free after slackening all of the retaining bolts.
Use a suitable chain block suspended from the crane hook to “break” the motor free after slackening all of the retaining bolts.
Use the full hoist facility to lift the motor clear in one action after removing all of the retaining bolts.
What could be the cause of a refrigeration compressor running continuously even though normal temperatures for the cold rooms have been reached?
Solenoid valve before the expansion valve stuck in closed position.
High-pressure cut-out is stuck in open position.
The differential pressure switch for the lubricating oil pressure cut-out is stuck in the closed position.
Low-pressure cut-out is stuck in closed position.
What is the correct name of the tool shown in the illustration?
What function is this operational amplifier circuit performing?
A piston rod retaining nut needs to be tightened during maintenance on the main engine. Which of the given methods should be used to ensure it does not come loose in service?
Tighten it as tight as possible using a flogging spanner and a hammer.
Tighten it 10 % more than the manufacturer’s recommendation using a torque wrench.
Tighten it to the manufacturer’s recommendations using a torque wrench.
Tighten it as tight as possible using a spanner and extension pipe.
When a ships derrick or crane lifts a weight off the deck of a ship, from which position can the centre of gravity of the weight be considered to act?
From the centre of the weight lifted.
From the position on the deck from which the weight was lifted.
From a position on the deck at the base of the derrick or crane.
From the head of the derrick or crane.
In a low pressure auxiliary boiler, what would be considered to be the maximum allowable chloride level of the boiler water?
What could cause diesel engine lubricating oil to appear cloudy with a slightly “milky” colour?
Fuel contamination of the system.
High temperature of the oil.
Water contamination of the system.
What is the correct name of the part highlighted in the illustration?
What would be the correct form of response to the question: “What kind of assistance do you require?”
The correct form of response would be: “There is a fire onboard my vessel”.
The correct form of response would be: “My vessel has a fire in the accommodation and we require fire-fighting assistance”.
The correct form of response would be: “I need help on board with a fire and the smoke is very toxic”.
The correct form of response would be: “I need help as soon as possible”.
What is the correct method to use for fitting a rolling contact bearing, such as a ball bearing, onto a parallel shaft?
Use a hammer and a pipe with the same diameter as the inner bearing ring and knock the bearing onto the shaft.
Use emery cloth on the bearing surface on the shaft.
Use emery cloth on the inner ring (contact surface) of the bearing.
Gently heat the bearing in an oil bath and use a bearing puller to draw it onto the shaft.
A seawater pump requires overhaul but there are no spare wear rings for the casing and impeller. It is decided that new wear rings will be fabricated onboard using the ship’s lathe. What would be the most suitable material to use to fabricate the rings onboard?
What is the most important task after carrying out any major overhaul on a diesel engine?
Start the auxiliary blower to ventilate the engine so that it has sufficient fresh air for starting.
Start the engine to check the direction of rotation.
A thorough check inside the engine to make sure all tools and cleaning rags have been removed.
Repair any damaged paint work on the engine.
What is the best method to use to remove heavy scale and fouling from the plates of a heat exchanger?
Use high-pressure cleaner with abrasive additives.
Soak the plates in recommended cleaning solution and then use a soft brush or pressure cleaner.
Use wire-brush metal scrapers and chipping guns.
What is the main reason for keeping engine lubricating oil viscosity within recommended limits?
To reduce system pressure losses.
To ensure the strength of the oil film is sufficient to keep lubricated surfaces apart.
To neutralise any acids that may form.
This device can detect a package of drugs inside a large delivery of ship’s stores. What is it?
Which of the following is not a principle of heat transfer utilised in an oil fired steam boiler?
An earth fault exists on the blue line of a 100 A bilge pump circuit. A second earth fault occurs on the yellow line of a 10 A ventilation fan circuit. The likely outcome is that:
Both motors trip out on overload.
A short circuit occurs between earth faults and the ventilation fan fuse blows.
A short circuit occurs between earth fault and the bilge pump fuse blows.
An open circuit occurs between earth fault and both motors trip out.
A power card taken from a diesel engine cylinder using a mechanical indicator has a flat top. Which of the possible actions given in the options is most likely to correct this irregularity on the power card?
Lengthen the cord for the indicator drum drive.
Change the indicator spring for one with a higher rating.
Shorten the cord for the indicator drum drive.
Lubricate the indicator piston and cylinder.
When referring to onboard oil treatments using a centrifuge, what is meant by the term purification?
Separation of solid contaminants from a liquid during the process.
Separation of two insoluble liquids with different densities, and the removal of solids in the same process.
It is a general term applied to a process for cleaning oil using a centrifuge.
Separation of one insoluble liquid from another.
An air compressor is being refitted in the engine room. The compressor and motor are coupled using a flexible coupling and are mounted on a common “skid” which fixed to the deck with resilient mountings. Which of the statements, from the options given, relating to the alignment of the motor and compressor is true?
Shims should be fitted between the motor and compressor feet and the skid to ensure correct vertical, horizontal and parallel alignment of the coupling halves before it is bolted up.
As long as the two coupling halves are at the same height the flexible coupling will accommodate any horizontal misalingment of difference in the gap between the coupling faces.
The compressor and motor can just be placed directly on the common skid as they will probably be closely aligned anyway.
Machines using flexible couplings and resilient mountings do not need to be aligned. That is why they have flexible and resilient elements fitted.
What will be the probable outcome if the amplification is set too high on a controller?
The process will oscillate and get out of control.
The set-point will change.
The process response will be very slow.
New MARPOL regulations came into effect from July 93 stating that the previous instantaneous rate of discharge of oil content (60 litters per nautical mile) was changed to:
10 litters per nautical mile.
25 litters per nautical mile.
30 litters per nautical mile.
20 litters per nautical mile.
What is the correct name of the part highlighted in the illustration?
Where would you find out which fire sections are enclosed by “A” or “B” class divisions on a ship?
All the mentioned alternatives.
On the general arrangement plan.
On the Ship’s fire control plans.
Which part of the crankshaft of a modern large two stroke diesel engine is most likely to be the origin point for crack initiation during service and therefore needs the greatest attention during maintenance inspection?
The dowel pins and dowel holes.
Which diagram is the symbol for a THYRISTOR?
On some large slow speed engines the crosshead guides are adjustable to allow the clearance between the crosshead shoes and the guides to be set equally. The normal arrangement is to have bolted on guide bars with shims fitted behind them. Which of the methods given in the options is the one normally used to ensure this is done correctly?
Fit an equal number of shims behind each guide bar which should result in equal clearances between the guide bars and shoes along the whole length.
Turn the engine so that the piston for the cylinder concerned is at TDC and measure the clearance along the length of each bar and shoe and fit shims to equalise the clearances.
Turn the engine so that the piston skirt is at the bottom of the liner. Use wedges to centralise the piston. Measure the clearances along the length of each bar and shoe and fit shims to equalise the clearances.
Turn the engine so that the piston for the cylinder concerned is at BDC and measure the clearance along the length of each bar and shoe and fit shims to equalise the clearances.
B Class divisions in ships are constructed so that they are capable of preventing the passage of flame to the end of a standard fire test held for:
A detector that is activated by a rise of temperature is:
What is the correct name of the tool shown in the illustration?
For ideal synchronising as the incomer circuit breaker contacts make, the phase angle difference between the incomer e. m. f. and the busbar voltage should be:
Which of the options represents the best action to take when an item of machinery, which normally operates in automatic mode, is operated in “manual” mode?
Keep the Chief Engineer informed of machines performance on an hourly basis.
Have someone permanently stationed at the machine in case of an operational problem.
Monitor the operation of the machinery on a frequent basis.
Change over all other machinery to manual mode of operation.
When you join a new ship, how are you informed about safety rules, alarm instructions and your own duties in case of an emergency?
By folder distributed to each crewmember.
By muster list exhibited in conspicuous places.
By alarm instructions in all crew cabins.
By oral instructions by the Captain.
An earth fault exists on the blue line of a 100 A bilge pump circuit. A second earth fault occurs on the yellow line of a 10 A ventilation fan circuit. Both systems are supplied from the ship’s 440 V supply. The likely outcome is that:
A short circuit occurs between earth faults and the ventilation fan fuse blows.
An open circuit occurs between earth fault and both motors trip out.
A short circuit occurs between earth fault and the bilge pump fuse blows.
Both motors trip out on overload.
PT-100 sensors are some times used with 3 or 4 wires. What is the reason for this?
Higher mechanical strength of the cable.
Because of power-consumption.
Higher measuring accuracy.
After main power is restored (following a blackout), a timed sequential restart of motor driven auxiliaries is necessary to avoid:
Generator overload due to many motors starting at simultaneously.
Overvoltage due to current surges.
Overloading creating earth faults.
Over-frequency due to overspeed of generator.
Which of the following alternatives summarise the benefits of using high voltage on ships?
Smaller conductors, machines and switchgear.
Smaller conductors, insulators and transformers.
Smaller cables and better power factors.
More efficient transformers and electrical machines.
What is the correct name of the tool shown in the illustration?
During maintenance of a piston rod stuffing box on a large, slow speed diesel engine it is usual to measure the butt gaps between the sealing ring and scrapper ring segments. What would be the effect of these gaps being too small?
If the gaps are too small the rings could scope the piston rod.
If the gaps are too small they could close due to the radial wear of the rings before the next scheduled overhaul preventing the rings from contacting the piston rod and sealing it.
If the gaps are too small then the flow of scavenge air through the gland would be reduced and the gland would overheat.
If the gaps were too small then no oil could pass up the piston rod to lubricate the sealing rings.
Why is it important to check the timing of diesel engine cylinder oil lubricators?
To ensure the piston is not covering the lubrication points and blocking the flow of cylinder lubricating oil into the cylinder.
To ensure cylinder lubricating oil enters the cylinders when the piston is in the required position.
To ensure the correct amount of cylinder lubricating oil is fed into the cylinders.
To avoid excess pressure in the cylinder lubrication system.
An electrical power emergency source in a ship is required because:
It satisfies the SOLAS requirements for ship safety.
The main diesel generator(s) can be taken out of service for overhaul or repair.
It satisfies the need to be environmentally “friendly”.
The ships total load can be shared between main and emergency generators.
What is likely to be the cause of black smoke from a diesel engine exhaust seen at the funnel?
Engine is burning some lubricating oil.
Incomplete combustion of the fuel.
How many separate means of escape are provided from each fire zone above the bulkhead deck?
What cooling medium is normally used to cool the condenser of a fresh water generator?
For ideal synchronising as the incomer circuit breaker contacts make, the phase angle difference between the incomer e. m. f. and the busbar voltage should be:
If a refrigeration system contains air, how would you remove it from the system?
Pump the system down to the evaporator and keep the fan running until the evaporator is at ambient temperature and vent off the air from the top of the evaporator.
Stop the compressor and vent the air from the crankcase.
Pump the system down to the condenser, continue cooling water flow until the condenser is at the same temperature as the cooling water and vent off the air from the top of the condenser.
Stop the compressor and undo a pipe coupling at the highest point in the system to vent off the air.
Select the option which best describes the primary duty of a watch-keeping engineer:
The primary duty of a watch-keeping engineer is to maintain constant surveillance of the main engine and auxiliary machinery.
The primary duty of a watch-keeping engineer is to maintain the ship’s speed.
The primary duty of a watch-keeping engineer is to ensure that machinery spaces are properly manned.
The primary duty of a watch-keeping engineer is to maintain constant surveillance of the steering gear.
What is the correct name of the part highlighted in the illustration?
During maintenance work on a compensated mechanical hydraulic governor air is drawn in to the hydraulic circuit after draining and flushing out the unit. Which of the actions given in the options is most likely to assist in the removal of the air from the system?
With the governor in operation open the compensation needle valve to introduce instability and disturb the engine load to make the governor hunt.
Overfill the governor with fresh oil to force all of the air out.
Drain the governor again and slowly refill with fresh oil.
With the governor in operation close the compensation needle valve and disturb the load to make the engine hunt.
Is it necessary to cool the samples taken from a diesel engine cooling water system before carrying out tests to determine the concentration of treatment chemicals?
No, the test should be carried out at system temperature.
Yes, the samples should be cooled to approximately 25 °C.
Yes, the samples should be cooled to approximately 50 °C.
No, the samples should be heated to approximately 95 °C.
For two generators running in parallel, their share of additional load (kW) will be determined by the:
Voltage droop setting on each AVR.
Governor droop settings on each prime mover.
The temperature difference between the generator rotors.
The power factor of the additional load.
With regard to radar, what would be a correct form of response to the question: “What range scale are you using?”
The correct form of response would be: “I am using the 12 mile range scale”.
The correct form of response would be: “I am using the largest range scale”.
The correct form of response would be: “I am using the 10 cm radar”.
The correct form of response would be: “I am using the 3 cm radar”.
When a fire breaks out in the accommodation, cargo holds or on deck, who is in charge of the fire fighting operations?
The first officer arriving at the scene.
The first person arriving at the scene.
The person who is designated in the muster list.
What is the most important task after carrying out any major overhaul on a diesel engine?
Start the engine to check the direction of rotation.
Repair any damaged paint work on the engine.
A thorough check inside the engine to make sure all tools and cleaning rags have been removed.
Start the auxiliary blower to ventilate the engine so that it has sufficient fresh air for starting.
What do you call the wide rung on a pilot ladder that prevents the ladder from twisting?
The wide rung on a pilot ladder that prevents it from twisting is called a “Spreader”.
The wide rung on a pilot ladder that prevents it from twisting is called a “Wide step”.
The wide rung on a pilot ladder that prevents it from twisting is called a “Long rung”.
The wide rung on a pilot ladder that prevents it from twisting is called a “Ani-twist rung”.
What is the main effect on lubricating oil of operating for long periods at excessively high temperature?
It will cause the oil to oxiside, increasing the viscosity.
It will cause the oil to oxidise, reducing the viscosity.
It will cause the oil to evaporate, increasing consumption.
It will change the flashpoint of the oil.
What is one of the main features of the cylinder lubricating oil used in large 2 stroke marine diesel engines which normally operate on heavy fuel oil?
It is neutral with a pH value of 7.
It is a pure mineral oil without any special additives.
A vapour compression refrigiration system is usually fitted with a number of devices to give protection and control of the system. Which of the methods given in the options should be used to test the high pressure cut out during routine maintenance and checking of the system?
Manually close each of the evaporator coils by switching off the electrical supply to the liquid line solenoid shut off valves and monitor the condenser pressure.
Close the condenser outlet valve and closely monitor the condenser pressure.
Gradually shut in the condenser cooling water valve or the condenser refrigerant inlet valve while closely monitoring the compressor discharge pressure.
Charge the system with refrigerant until the high pressure cut out operates.
Before leaving the machinery spaces of a UMS vessel after routine watchkeeping rounds in the evening, the duty engineer inspects the doors to Fuel Oil Treatment rooms which are covered by a fixed fire fighting installation. For what purpose does he do this?
To tie them open with a rope to prevent the heat from building up inside, and making it uncomfortable to work.
To make sure that they are properly closed with the self closing device so that any fire is contained and the extinguishing medium can be released without delay.
Wedge them open with an arrangement which allows them to be closed quickly in the event of a fire.quickly.
What type of component does this graphical symbol illustrate?
Pressure-reducing regulator.
You are starting to get low on water in the lifeboat. What should you do?
Mix sea water with 50 % fresh water.
What is the expansion ratio of the foam produced by the fixed low-expansion foam fire-extinguishing system of an engine room?
Greater than 20 to 1 but less than 50 to 1.
Personnel in a high voltage switchroom smell ozone. Which of the following is the likely cause?
Air circuit breaker problems.
Arcing at badly connected bus bars.
Vacuum circuit breaker problems.
What is the approximate content of oxygen in air?
Which ships does the ISM code apply to?
All passenger ships, all cargo ships of 500 GRT or above.
What acton is required if the crankcase relief valve on an air compressor is operating and emitting an air and oil mixture?
Increase the lift pressure of the relief valve.
Overhaul the compressor unit.
Increase the flow of cooling water to the compressor and intercooler.
Place a drip can beneath the valve to collect any escaping oil.
Many large slow speed diesel engines operating on heavy fuel oil have a fuel injection system which features Variable Injection Timing. How does this affect engine operation?
VIT increases engine efficiency by automatically maintaining the maximum cylinder pressure over the entire load range.
VIT increases engine efficiency by automatically maintaining the maximum cylinder pressure over part of the load range.
VIT improves engine operation by automatically controlling the start of fuel injection when it detects a poor quality fuel.
VIT allows the ship’s engineers to alter the injection timing for each load setting with a simple single adjustment of the fuel rack.
A seawater pump requires overhaul but there are no spare wear rings for the casing and impeller. It is decided that new wear rings will be fabricated onboard using the ship’s lathe. What would be the most suitable material to use to fabricate the rings onboard?
Vibration analysis is often used as a conditioning monitoring tool onboard ship as part of the approved planned maintenance system. Many vibration measuring instruments are fitted with a harmonic filter/analyser. How would these filters normally be used during vibration measurement on a centrifugal pump?
To block out any noise or vibration from the surrounding engine room.
To generate an audible sound signal at the same frequency and amplitude as the vibration.
To isolate a single frequency of vibration associated with one of the pumps components.
To sum up all the harmonics of a base frequency to give total vibration for all of the pump’s components simultaneously.
Before leaving the machinery spaces of a UMS vessel after routine watchkeeping rounds in the evening, the duty engineer inspects the doors to Fuel Oil Treatment rooms which are covered by a fixed fire fighting installation. For what purpose does he do this?
To tie them open with a rope to prevent the heat from building up inside, and making it uncomfortable to work.
Remove the auto closing device so they remain in whatever position.
Wedge them open with an arrangement which allows them to be closed quickly in the event of a fire.
To make sure that they are properly closed with the self closing device so that any fire is contained and the extinguishing medium can be released without delay.
What precautions should be taken, in addition to shutting the main air start valve if work is to be carried out inside the main diesel engine crankcase?
Keep a man posted in the control room to stop anyone who tries to start the engine.
Engage the turning gear and put a notice at each engine control position.
Engage the turning gear, stop the starting air compressors and drain the air receivers.
Engage the turning gear and close every valve on the starting air receivers.
As part of the regular maintenance for a paramagnetic oxygen analyser used for measuring the oxygen content of exhaust gas it is important to keep the sample line filter as clean as possible. Why is this necessary with this type of instrument?
The filter may rupture due to the high pressures generated by the sample pump.
Pressure variations in the sample chamber can cause errors so restrictions must be kept to a minimum.
The pressure drop across the filter may damage the sampling pump.
A high flow rate is required in order to deflect the sensing element.
Modern slow speed, two stroke diesel engines often have locating pins or pegs to keep the piston rings in a fixed position. Why is this arrangement used?
The piston ring gaps can be kept in line to control the gas pressure on each of the rings.
The piston rings are more difficult to lubricate because of the slow operating speeds and will wear more quickly if they are allowed to rotate.
It avoids the risk of the ends of the piston rings being forced out by the gas pressure and catching on the scavenge ports.
It ensures the rings cannot be mixed up and that they are fitted in the correct order on the piston.
What are the lists called that give the position and task during a lifeboat drill for all persons on board the ship?